Base Info
- Model NO.:km-E-100c
- Machine Power:3000W
- Spot Size:15*50mm,12*30mm,12*45mm
- Frequency:1~10Hz
- Name:IPL Elight,IPL Shr,Shr Hair Removal,IPL Laser
- Logo:Can Help Add in for Free
- Lamp:Shot Max 100, 0000 Times
- Transport Package:Aluminium Alloy Box and Carton Box
- Specification:CE, CCC, ISO13485, FDA
- Trademark:Health&Beauty
- Origin:China
- HS Code:9018909011
- Production Capacity:500ses,Month
Description
ipl shr device advantages
1. Digital frequency control system, energy output evenly and precisely
2. USB updating Technology,operating the machine and computer at the same time
3. Two operation modes-Touch and monse, much easier to operate the machine
4. 8.4" TFT true large color LCD touch screen with clear treatment parameters
Question & Answer
1. Which advantages does this have for you?
An optimal intensity can be achieved given that the same area is treated multiple times with
low energy impulses. The treatment is more comfortable and the skin is better protected than
with conventional methods.
2. How are different hair and skin colours affected?
Light skin with dark hair responds most favourably to the treatments. In addition to targeting the
melanin, SHR-technology affects the chromphore, a protein located in the follicle, enabling the
successful treatment of dark skin removing achromous, fine hairs.
3. What does the client feel during treatment?
Treatment with SHR is practically painless as opposed to treatment with the conventional IPL
devices. On areas with dense hair growth, warmth from the light impulses is evoked and the
light impulses may be felt to a much lesser extent than with laser or IPL.
4. Which areas can be treated?
Body hair can be removed on any part of the body. It is recommended a test be performed
on a small patch before the first treatment.
5. How many treatments are necessary?
Until now hair had to be treated during the growing phase (20%-30%). In the telogen phase
stem cells are in a resting phase but can still successfully be treated with the SHR system.
Since growth cycles vary, approx. 8 treatments are usually necessary.
6. How long should the intervals between treatments be?
The hair growth cycle and the interval between treatments should correspond requiring
spacing of approximately 6-8 weeks.
7. How much time is necessary for a treatment?
Depending on the size of the area to be treated, the time varies from 15 to 30 minutes for
a facial treatment and about 3 hours for both legs.
8. Will there be any side-effects?
Skin is more sensitive in some areas of the body than in others and redness can occur as
a side effect. It should disappear in a matter of hours but could potentially be as intense as
a sunburn lasting a few days. Contrary to conventional methods, a light crusting which will
vanish after 2-3 weeks, or an alteration of the sin's pigmentation which will disappear after
4-6 months, are very rare.
9. Precautions to be taken before the treatment?
At least 1 week before the first treatment, intense sun exposure or solarium visits should be
avoided. Hairs should not be waxed or plucked less than 6 weeks before treatment. Shaving
is permitted any time. Areas to be treated should be shaved one day before the scheduled
appointment.
10. Precautions to be taken after the treatment?
The skin's natural protection is highly weakened after this intense light treatment. Therefore a
high level of UV protection (30-50) in the form of suntan lotion should be applied for about
1 week.After 1-5 weeks hair will fall out. Shaving is possible any time but hair should not be
plucked.
Our mainly products are esthetic devices and medical beauty equipment
1.IPL Series
2.E-light(IPL&RF) Series
3.Cavitation Slimming Series
4.Vacuum Liposuction Series
5.808nm Diode Laser Hair Removal Series
6.Fractional Co2 Laser Series
7.Q-switched Nd Yag Laser Series
8.RF Radio Frequency Series
9.650nm Laser Slimming Series
10.Multi-functional Series
11. SHR hair removal and skin rejuvenation series
12. Fractional RF skin tightening series
Wavelength:
430/530/560/590/640~1200nmnm (Standard)
480/520/755~1200nm (Option) 560/585/640~1200nm (Option)
Treat head Spot size
12 x 30mm2 ; 8x40mm2; 15x50mm2 (Opitional)
Treat head Number
3 Treat Head
Cooling System
Air & Close Water Circuitlation & Treatment head
with semiconductor cooling temperature adjustable
IPL Light Energy
10~50 J/cm2 (adjustable)
Pulse Duration
2~15ms (adjustable)
Pulse Sequence
1~15 pulses (adjustable)
Delay Time
5~50 ms (adjustable)
Integrated Skin Cooling
-4degree~ +10degree
Operative Interface
8.4 inch TFT LCD true color touch screen